CONNECTING THE IA-204
WIRING
Microphone and line input signals require shielded cables.
If using the RCM-42B Room Combining Matrix, use shielded cables to connect the RETURN and SEND
between the IA-204 and RCM-42B. Each IA-204 is shipped with jumpers on the seven pin orange screw
terminal connector between pins 4 and 6, and 5 and 7. These need to be removed if you are using the RCM-
42B. These jumpers are necessary to connect the SEND and RETURN when no RCM-42B is connected.
A two conductor non-shielded wire is used to connect the ROOM MIXING switch to the RCM-42. If you
are using a remote room combining switch, separate from the IA-204, you will need a three conductor wire
(see room combining section for more detail).
Ground all cable shielding only at the IA-204! Do not ground mic or line inputs to conduit, as this can create
ground loops and cause noise and system oscillation.
All cables should be brought at least 6” beyond the 4 gang electrical box for ease of installation and future
service.
All connections should be terminated with the proper connectors supplied with the IA-204.
To avoid electrical interference, signal cables should not run close to exposed high voltage wiring.
Be sure to follow local building codes.
RECOMMENDED CABLES
The following cable types are recommended:
2 Conductor shielded for microphone and line inputs.
2 pair (each containing 2 conductors) individually shielded for SEND and RETURN
connections between the IA-204 and RCM-42B. (Belden 8723, West Penn 510, or
equivalent)
2 conductor non-shielded for the ROOM MIXING control lines (if using the RCM-
42B).
IA-204 INSTALLATION
WARNING! The IA-204 uses a bridging amplifier circuit. Do not ground either of the speaker outputs. If connecting
a headphone jack, make sure it is insulated from ground!
All wiring to the IA-204 is low voltage and connects to the IA-204 with removable screw terminal
connectors.
Remove the screw terminal connector from the IA-204, insert the bare wire end into the desired slot, and
tighten the screw to secure the wire in place.
Verify all wire connections and take care not to reverse the screw terminal connectors when replacing them
on their respective circuit board terminals.
When the screw terminal connectors are properly oriented, all wiring faces down toward the bottom of the 4
gang electrical box.